US$3.95-6.00
|
1,000 Pieces
(MOQ)
|
Basic Info.
Medium Temperature
Cold Water
Counter Instructions
Digital
Principle
Speed of Water Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Transport Package
Export Carton
Specification
Plastic body, Plastic connectors
Production Capacity
100, 000/Month
Packaging & Delivery
Package Size
50.00cm * 30.00cm * 25.00cm
Package Gross Weight
16.000kg
Product Description
Multi-jet, Dry dial
Body material: Nylon Plastic
Sizes: DN15 to 50mm( 1/2" - 2"), available for cold water (40°C)
Accuracy: ISO4064, Class B standard
Easy for interchange & maintenance
MAIN TECHNICAL DATA
Meter size Dia DN (mm) | Class | qs Overload Flow | qs Nominal Flow | qs Transitional Flow | Qmin Min Flow | Min Reading Lectura | Max Reading Lectura |
| m3/h | 1/h | m3 |
| 15 | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
| B | 120 | 30 |
| 20 | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
| B | 200 | 50 |
| 25 | A | 7 | 3.5 | 350 | 140 | 0.0001 | 99999 |
| B | 280 | 70 |
| 32 | A | 12 | 6.0 | 600 | 240 | 0.0001 | 99999 |
| B | 480 | 120 |
| 40 | A | 20 | 10 | 1000 | 400 | 0.001 | 99999 |
| B | 800 | 200 |
| 50 | A | 30 | 15 | 4500 | 1200 | 0.001 | 99999 |
| B | 3000 | 450 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN (mm) | Length | Width | Height | Connecting Thread D | Weight Kg |
| mm |
| 15 | 165 | 99 | 104 | G 3/4B | 0.53 |
| 20 | 190 | 99 | 106 | G 1B | 0.6 |
| 25 | 225 | 104 | 120 | G1 1/4B | 0.74 |
| 32 | 230 | 104 | 120 | G1 1/2B | 0.82 |
| 40 | 245 | 125 | 155 | G 2'B | 1.2 |
| 50 | 300 | 125 | 155 | G2 1/2 B | 1.46 |
WORKING CONDITION
Water temperature:≤40ºC for cold water meter
Working pressure:≤1.6Mpa