| US$67.00-73.00 | 10 Pieces (MOQ) |
| Specifications | SC100 | SC105 | ||
| Power Requirements | Supply Voltage | 8-16VDC, nominal 12VDC | ||
| Current Consumption | Typical 3mA @ 12VDC | |||
| Sensitivity | Adjustable Sensitivity | 4 levels by DIP Switches | ||
| ATMs/Vault Selection | by DIP switch | N/A | ||
| Delayed Triggering | N/A | by DIP switch | ||
| Reduced Sensitivity Input | For maintenance & Service: Active low (<1.5 VDC) | |||
| Detection Radius | 16.4' | 9.8' | ||
| Alarm Algorithm | Highly sensitive to all known attacks while rejecting known false alarm sources by innovative filters and firmware | Similar to the SC100, but adjusted for noisy environments such as public areas where ATMs may be located | ||
| Alarm Outputs | Solid State Relay (Change Over) | 30VDC/100 mA; Type C | 30 VDC/100 mA; Type A | |
| Open Collector | Active low during alarm | |||
| Alarm Hold Time | Approx. 2.5 secs | |||
| Sabotage Protection | Pry-off and Cover Switch | 30 VDC/100 mA | ||
| Low Supply Voltage Alarm | < 7 VDC | |||
| Temperature Alarm | 185° F, 23° F, 41° F | |||
| Internal Functional Alarm | Stainless steel drill shield | |||
| Inputs | Remote Test | Active low 1.5 VDC, test duration < 0.5 sec | ||
| Reduced Sensitivity Input | Active low 1.5 VDC, test duration < 0.5 sec Sensitivity reduction to 12.5 % | |||
| Installation Tool | A noise and alarm indicator is incorporated to support sensitivity setting. | |||
| Environmental Conditions | Maximum Humidity | 95% RH (non-condensing) | ||
| Operating Temperature | -40° F - 158° F | |||
| Storage Temperature | -58° F - 158° F | |||
| Environmental Class (VdS) | III | |||
| Housing Protection Category | IP43 | |||
| Housing | Dimensions | 3.15" H x 2.36" W x .83" D | ||
| Chassis and Cover | Die-cast metal | |||
| Color | RAL7035 (light gray) | |||
| Weight | .5 lbs. | |||
OEM/ODM Service | we have been provided OEM/ODM for more than Many companies |
After sale service | One year warranty |
Certificates | CE |