Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
The Expiratory Hold procedure is used to measure the end breath lung pressure. When Expiratory Hold is selected, the inspiratory and expiratory valves close at the end of the next expiratory phase. The expiratory hold cannot be repeated until the patient triggers a spontaneous breath or the ventilator delivers a mandatory breath. Expiratory Hold is not available in non-invasive ventilation modes. 1. Select as a Favorite (the procedure will start immediately) - see "Setting Favorites" in the Operation section or select Menu > Procedures > Expiratory Hold. 2. Select the Expiratory Hold time. • Use the Trim Knob to select an Expiratory Hold time between 2 to 60 seconds for adult, 2-20 seconds for pediatric and neonatal. 3. Select Start. • A general message shows while the expiratory hold is in progress. • The procedure will end when the Hold Time has elapsed or when Stop is selected. CARESCAPE™ R860 7-8 2065490-001 Manual breath The Manual Breath procedure allows the clinician to deliver additional mechanical breaths to the patient. The ventilator requires a 0.25 second pause between delivery of breaths. The breath delivered is based on the settings for the current mode or backup ventilation mode if a rate is not set for the current mode. Manual Breath is not available in non-invasive ventilation modes. Select as a Favorite (the procedure will start immediately) - see "Setting Favorites" in the Operation section or select Menu > Procedures > Manual Breath > Add Breath. 7 Procedures 2065490-001 7-9 Measuring P 0.1 P 0.1 is a respiratory measurement used to evaluate the patient’s readiness to be weaned from the ventilator. P 0.1 is a measurement of the airway occlusion pressure 0.1 second after beginning an inspiratory effort against an occluded airway. 1. Select as a Favorite. See "Setting Favorites" in the Operation section or select Menu > Lung Mechanics > P 0.1. 2. Select Start. • The P 0.1 measurement will display along with a timestamp. • The P 0.1 procedure will end when the measurement is completed or when Stop is selected. If the measurement is not available, a red X will display indicating a failure