US$100.00-500.00
|
2 Pieces
(MOQ)
|
Basic Info.
Certification
CE, RoHS, ISO
Type
Electrochemical Gas Analyzer
Gas Sensor
Advanced Sensor Made in UK
Detection Principle
Electrochemical & Infrared & Pid
Explosion-Proof Grade
Ex D Iic T6
Sensor Life
2 Years for Electrochemical
Environment Temperature
-10c~50c
Transition Cable
Rvvp 3*1.5mm2
Specification
235*175*135mm
Production Capacity
10000/Month
Product Description
Wall-mounted gas detector for 0-100ppm hydrogen sulphide with SIL2 Introduction
4-20mA Fixed gas detector with OLED display and advanced British CITY sensor is a classic product of AIYI Technologies, which is suitable for most areas where it is necessary to detect flammable gas, oxygen, and toxic gas. The product responds quickly with an advanced gas sensor; ingress protection to IP65.
Features
-Advanced gas sensors, fast response with a long lifespan, safer and more reliable.
-IP65 design with body material in stainless steel and aluminum alloy, suitable for harsh environments.
-High-brightness OLED display, capable to see readings in any angle.
-Built-in relay and compatible with sound light alarm Full English menu, remote control operation.
-Complete product certification (ATEX, SIL2, CCCF, etc.)
Specifications
Description | Specifications | Anr | AG210 |
Gas Detected | | | |
Ex | catalytic combustion | √ | - |
toxic gas | electrochemical | - | √ |
infrared | - | √ |
PID | - | √ |
Function | | | |
measure range | see QUICK-SELECTION-TABLE | √ | √ |
response time* | T90≤30S | √ | - |
T90≤60/180S | - | √ |
accuracy* | ≤±5%F.S | √ | √ |
repeatability* | ≤2%F.S | √ | √ |
Electric | | | |
power supply | 18-28VDC (standard 24VDC) | √ | √ |
power consumption | ≤2.5W | √ | - |
≤1.5W | - | √ |
signal output | 4-20mA | √ | √ |
RS485 | - | - |
wiring | three-wire | √ | √ |
four-wire | - | - |
suitable cable | RVVP3*1.5mm2 | √ | √ |
RVVP4*1.0mm2 | - | - |
relay output | 1 passive relay (250VAC/5A 30VDC/5A) | √ | √ |
Display&operation | | | |
display | OLED display | √ | √ |
indicator light | power,fault,alarm-1,alarm-2 | √ | √ |
operation method | key operation | √ | √ |
Environment | | | |
ingress protection | IP65 | √ | √ |
operating temperature | -40ºC~70ºC | √ | - |
-20ºC~60ºC | - | √ |
operating humidity | 10~95%RH non-condensing | √ | √ |
operating pressure | 80-120kPa | √ | √ |
Structure | | | |
body material | ADC12 aluminum alloy +316L stainless steel | √ | √ |
close nipple | NPT1/2 | √ | √ |
weight | about 1.5kg | √ | √ |
dimensions | 165*140*78mm(H*W*D) | √ | √ |
Certificates | | | |
CPA | 2013C293-32 | √ | √ |
EX | ExIICT6 Gb | √ | √ |
CCCF | 073184850124ROM | √ | - |
SIL | SIL2 | √ | √ |
ATEX | ExdIICT6 Gb | √ | √ |
Note:* refers to there's some difference vary from different gas, please contact the manufacturer for details. |