| Negotiable | 5 Pieces (MOQ) |
| Cell | model | GLP10Ah-7768256 | |
| Capacity(0.5C) | ≥9Ah | ||
| rated voltage(V) | 3.2V | ||
| Typical Impedance (mΩ) | ≤5mΩ | ||
| Battery material | NMC cathode material | ||
| PACK | Combination method | 1P12S | |
| Minimal capacity(0.5C) | 9Ah | ||
| Nominal voltage | 36V | ||
| Max. charge voltage | 43.8V | ||
| Discharge cut-off voltage | ≤30V | ||
| Max Charge current | 5A(0.5C) | ||
| Max Working current | 15A(1.5C) | ||
| Standard charge current | 0.3C | ||
| Standard charge current | 0.5C | ||
| Pack Impedance standard | ≤100mΩ | ||
| Weight (Approx.) | 4Kg | ||
| Max. dimension(L×W×H)(mm) | 76*107*380 | ||
| Operating temperature | Charge temperature | 0ºC~45ºC | |
| Discharge temperature | -20ºC~60ºC | ||
| BMS | Single cell over-charge cut-off voltage | 3.7V | |
| over-charge release voltage | 3.6V | ||
| Single cell under-discharge cut-off voltage | 2.5V | ||
| Discharge release voltage | 2.7V | ||
| Over-discharge cut-off current | 40A | ||
| Over-discharge cut-off current delay | 1.5S | ||
| Short-circuit protection | 45A | ||
| Short-circuit protection delay | 500uS | ||
| Condition for the recovery of over-current and Short-circuit | | ||
| Balance current | 40-50mA | ||
| Balance Condition | 3.6 | ||