Basic Info.
Frequency Characteristics
Df
Application Range
Industrial and Mining Enterprises
Input
3.3VDC, 5VDC, 9VDC, 12VDC, 15VDC,24VDC,etc
Output
+/-3.3VDC,+/-5VDC,+/-12VDC,etc
Isolation Voltage
3000VDC
Transport Package
Color Box
Specification
ISO9001: 2008, CE, RoHS
Production Capacity
50000PCS/Year
Product Description
High Isolated Unregulated DC to DC Converter EXXXXS/D-1W
Features:
Low cost, small size.
High power density.
High galvantic isolation.
No heat sink required.
Regulated single output.
Fixed input, Unregulated Dual Output
3KV isolation.
Rated 1W, 2W output.
Industrial standard pin-out.
PCB Mounting.
Applications:
Electric Power System, Power monitoring, voltage conversion.
Dual power isolation in digital communication ports of RS232/485, CAN bus.
Power supply isolation in intelligent control, security equipments, telecom, etc.
Safety isolation in ground loop elimination, medical equipments and instrument.
Isolation & power supply for analogue electric circuit ( Transmitter & sensors).
Power supply isolation & transfer for safety monitoring and smart building system.
Ground loop interference control.
Car electric circuit power isolation & distribution.
Battery power supply, voltage transfer, power distribution.
PLC, DCS, PC isolation regulated power supply.
OUTPUT SPECIFICATIONS |
Items: | Testing condition | Min | Typ | Max |
Output accuracy: | At full load and nominal Vin | | | ± 5% |
Output power: | | 0.1W | 1W | 1W |
Line regulation: | For Vin change of 1% | | | 1.2 |
Load regulation: | From 20% to full load | | 10% | 15% |
Ripple and noise: | 20MHz bandwidth | | | 150 mV p-p |
Temperature drift: | | | | ± 0.02%/° C |
Minimum load | | | | 10% |
Switching frequency | | | 100KHz | |
Over load protection | % of FL at nominal input | | 120 | |
Short circuit protection | | Momentary |