Basic Info.Model No.: COB-64YK
Trademark:VIBBA /OEM
Quality: Superior quality
Application: Industrial Machinery
Remote control distance: Up to 100 meters
Operating Temperature: -35ºC---+80ºC
Source Voltage: 380V/220V/36V
Warranty time: One year
Product Description
Features
1. Advance program design, quick & good performance on movements.
2. IP65 water/shock/dust proof.
3. Low-power design: 1.5 volt battery*2 PCS
4. The shell adopts durable glass fiber stucture.
5. Super wide range of operating tempretures:-35ºC--+80ºC
6. Self inspection and don't repeat the 32-bit indentification No.
7. Operating distance ranges up to 100-150 meters.
8. With 10 action button,a stop button,9 single speed button
9. It can be widely used in various industrial equipment.
Transmitter
Technical date:
Operation distance: 100 meters
Temperature: -35ºC--+80ºC
Power supply: 1.5V(AA)*2 PCS
Enclosure: IP65
Consumption: <17mA(stand by: <20mA)
Address code: 4.2billions sets
Size:16.4*7.5*4.6 cm
Weight: 320g
Receiver
Technical data:
Antenna: Internal type
Temperature: -35ºC--+80ºC
Source Voltage: 380V/220V/36V
Enclosure: IP65
Consumption: <12W
Security Code: 4.2 billions sets
Size:18.5*8.5*8.5 cm
Weight: 550g
Power-On steps:
1. Power-on receiver
2. Switch the power switch to ON, and turn on the mushroom.
3. Press any button and release, now is ready to operate(now receiver powder LED light is green)
Power-Off steps:
1. Push down the mushroom.
2. Switch off transmitter power to cut off the power.
Installation Notes:
1. Ensure the original wired control of crane works.
2. Shut down crane main power source before installation.
3. Mount in a firmed side where the receiver can be seen easily by operator.
4. Keep away the mounted side from motors relays, cables, high voltage wiring and devices, or the protrusion of building where crane moves, select firmed side without metal shield.
5. Do not install the other same channel remote controller within 50M.
6. Ensure the wiring layout correctly and safely
7. Test each function to be sure each out put has the same function as wired control
8. Put the wired pendant in safe position.