Product Details
Product Details
Product Description
Product Description
Brand:EATON
Type:XV-440-10TVB-1-20
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
The Remote Extr/Adm Setpoint range is determined by the programmed analog input’s 4 mA and 20 mA settings. The Remote Extr/Adm Setpoint range is tunable in the Service mode, but cannot be set outside of the min and max Extr/Adm Setpoint settings. When enabled, the Remote Extr/Adm Setpoint may not match the Extr/Adm setpoint. In this case, the Extr/Adm setpoint will ramp to the Remote Extr/Adm Setpoint value at the programmed ‘Extr/Adm Setpoint Rate’ setting (as defaulted in the Service mode). Once matched, the fastest the Remote Extr/Adm Setpoint can move the Extr/Adm setpoint is limited by the programmed ‘Rmt Ext/Adm Setpt Max Rate’ setting. If the ‘Rmt Extr/Adm Setpt Max Rate’ were set at 10 and the Remote Extr/Adm Setpoint analog input instantly moved from 0 units to 1000 units, the Extr/Adm setpoint will move to 1000 units at 10 units/sec. If the milliamp signal to the Remote Extr/Adm Setpoint input is out of range (below 2 mA or above 22 mA) an alarm will occur and the Remote Extr/Adm Setpoint will be inhibited until the input signal is corrected and the alarm is cleared. Remote EXTR/ADM Setpt Messages Depending on configuration and system conditions, the Remote Extr/Adm Setpoint may be in one of the following states (505E front panel screen messages): • Disabled—The Remote Setpoint function is disabled and will have no effect on the Extr/Adm setpoint. • Enabled—The Remote Setpoint has been enabled, but permissives are not met. • Active—The Remote Setpoint has been enabled, and permissives are met, but Extr/Adm PID is not in control. • In Control—The Remote Setpoint is in control of the Extr/Adm setpoint, and the Extr/Adm PID is in control. • Inhibited—Remote Setpoint cannot be enabled; Remote Setpoint input signal is failed, Extr/Adm input signal is failed, or a controlled stop is selected. Remote EXTR/ADM Enable Logic There are three different options for enabling Remote Extr/Adm Setpoint and Extr/Adm control.
They are as follows: • One Remote Enable contact input or function key command programmed • Both the Remote Extr/Adm Enable and Extr/Adm Enable commands programmed • No enable commands programmed When only one Remote Enable command is programmed (either F-key or contact input), selecting ‘Enable’ will enable both Extr/Adm control and Remote Extr/Adm control. This configuration allows both functions to be enabled with one command if this is the normal operation mode. If ‘Disable’ is selected, both control modes are disabled.