Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
Backup ventilation is available in BiLevel mode. To set a Backup Mode, select Current Mode > Mode Settings and select Backup Mode. The following settings are available in BiLevel mode: Category Setting Main Parameters FiO2 Pinsp PEEP PS Breath Timing Rate Tinsp Patient Synchrony Insp Trigger Exp Trigger Bias Flow PS Rise Time Rise Time Safety Pmax Note Note CARESCAPE™ R860 5-26 2065490-001 AB.100.203 1 2 3 4 7 5 6 8 Figure 5-9 • BiLevel waveforms 1. Airway pressure (Paw) waveform 2. Tinsp 3. Exp time 4. Pressure Support (PS) 5. Pinsp 6. PEEP 7. Flow waveform 8. Tidal Volume (VT) 5 Ventilation modes 2065490-001 5-27 BiLevel airway pressure ventilation volume guaranteed (BiLevel VG) BiLevel VG mode is a purchasable option. During BiLevel VG mode, if the patient initiates a breath at the PEEP level, a pressure-supported breath at the PS setting is delivered. The ventilator alternates between a set PEEP and the minimum pressure to deliver the set tidal volume (VT) based on the set Rate and Tinsp. To determine the patient’s lung compliance, the ventilator delivers volume-controlled ventilation for 10 seconds or two inspiratory periods, whichever is longer when the mode is initiated. Based on the patient’s lung compliance, the inspiratory pressure is established and used for subsequent breaths. The ventilator uses the following pressure range when adjusting inspiratory pressure: • Low limit: PEEP + Pmin • High limit: Pmax - 5 cmH2O The difference in inspiratory pressure between breaths does not exceed ±3 cmH2O. If the patient initiates a breath at the PEEP level, a pressuresupported breath at the set PS setting is delivered. If a high airway pressure alarm is active for the current breath, the next breath’s pressure target is 0.5 cmH2O lower. Backup ventilation is available in BiLevel VG mode. To set a Backup Mode, select Current Mode > Mode Settings and select Backup Mode. Tube Comp, Leak Comp, and Trigger Comp may be set if desired. The following settings are available in BiLevel VG mo