Basic Info.
Grid Type
off-Grid Inverter
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Max. Output Efficiency
90%
Output Waveform
Pure Sine Wave
DC Reverse Connection Protection
Fuse Burnt
Working Temperature
-10ºC~50ºC
Unit Size
365mm*210mm*92mm
Short Circuit Protection
Yes
Display
LED or LCD Display
AC Output Voltage (Single Choice)
100V/110V/120V/220V/230V/240V
Transport Package
Carton or Plywood Case
Specification
365mm*210mm*92mm
Production Capacity
50000/Year
Packaging & Delivery
Package Size
36.50cm * 21.00cm * 9.50cm
Package Gross Weight
5.480kg
Product Description
WHP-2000 OFF Grid Pure Sine Wave DC to AC Power Inverter High Quality 2000W 12V 24V 48V to 110V 220V High Efficiency Inverter Note:
1. We have enough capacity to produce your customized order.
2. Samples are available.
3. High quality and competitive price.
4. 1 year warranty, please rest assured to buy.
Model | P-1500W-12V | P-1500W-24V | P-1500W-48V |
Output Power | 1500W |
Peak Power | 3000W |
DC Input Voltage Range | DC12V(9.5V-15.5V) | DC24V(19V-31V) | DC48V(38V-62V) |
AC Output Voltage (Single Choice) | 100V/110V/120V/220V/230V/240V |
Unload Current | ≤0.6A | ≤0.3A | ≤0.2A |
Output Frequency | (50Hz±2Hz) or (60Hz±2Hz) |
Output Waveform | Pure sine wave |
Display | LED or LCD display |
USB Output Votlage / Current | 5V 2A (Support QC3.0 fast charge up to 18W) |
Max. Output Efficiency | 90% | 92% | 95% |
Low Voltage Protection | "Alarm ""Bi"" with 2s interval +red and green lights flashing alternately restart automatically when voltage recover" |
Over Voltage Protection | " Alarm ""BiBi"" with 1s interval +red and green lights flashing alternately restart automatically when voltage recover" |
Over Load Protection | "Alarm ""Bi"" continously +red light flashing / restart automatically when load power recover; If it is closed after twice recover, it need restart manually." |
Over Temp Protection | " Alarm ""BiBiBi"" with 1s interval +red and green lights flashing alternately restart when temp recover" |
Short Circuit Protection | yes |
DC Reverse Connection Protection | Fuse burnt |
Low Voltage Alarm Range | 10.5v±0.5v | 21v±0.5v | 42v±0.5v |
Low Voltage Protection Range | 9.5v±0.5v | 19v±0.5v | 38v±0.5v |
Low Voltage Recover Range | 12v±0.5v | 23v±0.5v | 46v±0.5v |
Over Voltage Protection Range | 15.5v±0.5v | 31v±0.5v | 62v±0.5v |
Over Voltage Recover Range | 14v±0.5v | 28v±0.5v | 56v±0.5v |
Working Temperature | -10ºC~50ºC |
Cooling Method | Fan cooling (Temperature control) |
Unit Size | 335mm*180mm*76mm |
N.W/G.W | 3.42kg/4kg |