| US$2,900.00-3,100.00 | 1 Piece (MOQ) |
FOCUS ON OIL FILTRATION SYSTEM OVER 20 YEARS Recycling your used oil reduces pollution and protects our environment. Conserving a valuable resource and getting paid for it. Chongqing TOP Oil Purifier Co.,Ltd. |
| # | Parameter description | Measurement units | Value |
| 1 | Measured petrols octane numbers range | ON | 40-135 |
| 2 | Acceptable limit of octane number measurement basic error, max | ON | ±0.5 |
| 3 | Limit of acceptable difference between parallel octane number measurements, max | ON | ±0.2 |
| 4 | The determination range of antiknock additives content in petrols | % | 0.5-15 |
| 5 | Acceptable basic error limit of antiknock additives content determination in petrols | % | 0.1 |
| 6 | Petrol oxidation breakdown time measurement range | Min | 50-2400 |
| 7 | Acceptable basic error limit of petrol oxidation breakdown time | % | 5 |
| 8 | Petrol quality determination mode basing on volume resistivity | Ohm | 10 6-10 14 |
| 9 | Acceptable basic error limit of volume resistivity measurements | % | 3 |
| 10 | Cetane numbers measurement range | CN | 20-100 |
| 11 | Acceptable basic error limit of cetane numbers, max | CN | ±1.0 |
| 12 | Acceptable difference limit between cetane numbers parallel measurements, max | CN | ± 0.5 |
| 13 | Acceptable error limit when determining diesel-fuel pour point | ºC | 2 |
| 14 | Kerosine content determination range in summer diesel fuels | % | 0-50 |
| 15 | Acceptable basic error limit when determining kerosene content in diesel fuels | % | 3 |
| 16 | Mode for pour point depressants content determination for diesel fuel | % | 0.2-1 |
| 17 | Acceptable basic error limit when determining of pour point depressants content | % | 0.01 |
| 18 | Motor oils clarity level measurement range | % | 50-100 |
| 19 | Acceptable error limit of motor oils clarity level measurement | % | 0.1 |
| 20 | Acceptable difference limit between motor oils clarity parallel measurements | % | 0.01 |
| 21 | POL dielectric permeability measurement range | units | 1-5 |
| 22 | Acceptable error limit of dielectric permeability measurement, max | unit | 0.001 |
| 23 | Acceptable difference limit between POL dielectric permeability parallel measurements, max | unit | 0.001 |
| 24 | Oils base number determination range | unit | 3-24 |
| 25 | Acceptable basic error limit when determining oils basic number | BN unit | 1 |
| 26 | Motor oils manufacturer and brand determination | Manufacturer | - |
| 27 | Circuit-breaker oils (dielectrics) breakdown voltage measurement range | kV | 5-100 |
| 28 | Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max | kV | 1 |
| 29 | Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max | kV | 0.2 |
| 30 | Measurement range of circuit-breaker oils loss angle tangent | % | 0.01-40 |
| 31 | Acceptable error limit of circuit-breaker oils loss angle tangent, max | % | 0.01 |
| 32 | Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max | units | 0.001 |
| 33 | Determination range for mechanical impurities content in oil products | % | 97-100 |
| 34 | Acceptable basic error limit when determining mechanical impurities content in oil products | % | 0.01 |
| 35 | Water-in-oil content determination range for oil products | % | 0-30 |
| 36 | Acceptable basic error limit when determining water-in-oil content of oil products | % | 1 |
| 37 | Measurement time | sec | 1-5 |
| 38 | Insufficient power supply indication operation threshold | V | 5.4 |
| 39 | Instrument useful life | 6 | |
| 40 | Overall dimensions of: | ||
| electronic module | mm | 100х210х40 | |
| sensor #1 and #2 | mm | 60х100 | |
| Instrument mass with one sensor/two sensors | g | 850 / 680 |
| MOQ | 1 Set |
| Trade Terms | EXW, FOB, CIF, CFR |
| Payment Terms | T/T, L/C |
| Port of Loading | Any Port of China |
| Packing Method | Internaional Standard Wooden Case |
| Transportation Method | By Sea, By Land, By Air, By Express |
| Supply Capability | 100 Sets/Month |