US$1,170.00
20-499 Pieces
Basic Info.
Classification
Lighting/Power
Standby Time
Standard Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Rated Voltage
380VAC 3phase with Ground
Rated Frequency
40-70 Hz (50/60 Auto-Sense)
Voltage Regulation
220VAC (+/-1%)
Frequency Regulation
50/60Hz
Power Factor
0.7/0.8 (Optional) Standard 0.7
Voltage Distortion
Linear Load<3% Non-Linear Load<6%
Operation Temperature
0~40degree Centigrade
Transport Package
Carton, Export Type Packing or According to Your R
Specification
260X570X717
Product Description
Key attributes Other attributes Warranty 3months-1year
Place of Origin Guangdong, China
Brand Name ENSURE
Model Number MPS9335C II
Phase Three Phase
Protection Unbalanced Loads
Weight 41.3KG
Type modular UPS
Application Networking
Name MPS9335C II
Capacity 50-720KVA
Packaging and delivery Packaging Details carton
Port Shenzhen
Supply Ability Supply Ability 5000 Piece/Pieces per Month Application IDC(Internet Data Center),computing center, ISP (Internet Service Provider ),Telecom,Finance bank and securities, Tax, hospital system, industrial automation, precision equipment, etc.
Working principle Modular UPS uses double conversion online structure, including rectifier, inverter, charger, control circuit, input and output and battery linker, circuit breaker, input power factor compensation, etc. All modules can be hot swapped online, providing a high level of availability and maintainability. A control module failure will not affect the normal operation of the system. The control module can Online hot swap replacement. The parallel connection of power modules is also centrally managed by the control module acccording to the unified parallel parameters. The single one power module failure can be automatically withdrawn. The parallel system will not cause harm to the entire parallel. Modular UPS system uses independent static bypass module not adopt multiple static bypass circuit structure to avoid overload loss caused by uneven flow of multiple bypasses when switching to bypass mode. The output voltage accuracy of the module in parallel is ± 1%, and the parallel circulating current is <1%. The static bypass module contains only the bypass static switch, not includes the static output of the main circuit static switch. therefore, the replacement of the static bypass module will not cause the system power off or turn to manual maintenance bypass. The online hot-swap replacement also can be realized in battery mode.
Model | MPS9335C II 50-720KVA |
Capacity | 50-720KVA |
Main Input |
Input voltage | 380V/400V/415VAC |
Input Frequency Range | 50/60Hz |
Power Factor | >0.99 |
THDi | THDi<3% |
Input power soft-start function | 5-30S settable |
Input Voltage Ranges | 228V-476V;-20% ~ 25% at Full load ; linear derating at -25% ~ -40%; can take 70% load at -40% |
Frequency Range | 40-70Hz |
Battery |
Battery Voltage | ±240VDC,12V Battery 32~44 pcs can be chose |
Charge Voltage accuracy | ±1% |
Bypass |
Bypass Input Voltage | 380/400/415VAC 3-phase 4-wire |
Voltage Range | Default value is -20%~+15%; -40%,-30%,-10% ~ +10%,+15%,other ranges can be set via software |
Overload Capacity | Long term at 135% rated load,150%<load<180% more than 10 min,load> 1000% 100ms |
Ouput |
Inverter Output Voltage | 380/400/415VAC 3-phase 4-wire |
Voltage Accuracy | ±0.5% (balanced load),±1% (unbalanced load) |
THDV | THDV<1%(linear load), THDV<3%(nonlinear load) |
Power Factor | 1.0 |
Three Phase Angle accuracy | 120°±0.5° |
Current Crest Ratio | 3:1 |
Overload Capacity | 110%1h,125%10mins , 150%1mins,> 150%200ms |
Transfer Time | <2ms |
System |
Frequency | 50Hz/60Hz(Settable) |
Mains synchronization range | ±2Hz(Default value),adjustable with step of 0.5Hz within range of+/-0.5Hz-3Hz |
Protection Level | IP20 |
Communication Ports | RS232.RS485,dry contact ,SNMP card,EPO,generator port |
System efficiency | >97% at load above 50%,>95%at load above 25%, |
Operation Temperature | 0~40ºC |
Storge Temperature | -25ºC~70ºC(without battery) |
Humidity | 0~95%(no-condensing) |
Noise(dB) | 55-62dB,Adjusted with load |
Weight Dimension(WxDxH)mm | module:PM 50 | 50KVA power module :41.3KG |
module:PM60 | 60KVA power module:41.3KG |
3 module cabinet | 600X1000X1400 |
5 module cabinet | 600X1000X2000 |
8 module cabinet | 1200X1000X2000 |
12 module cabinet | 1800X1000X2000 |
power module | 440X638X217-(50/60KVA) |