Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
The Aerogen® Professional Nebulizer System is a portable medical device for multiple patient use that is intended to aerosolize physician-prescribed solutions and suspensions for inhalation to patients on and off ventilation or other positive pressure breathing assistance. The CARESCAPE R860 supports the Aerogen Professional Nebulizer System (Aerogen® Pro and Aerogen® Solo). Both nebulizer devices operate in-line using the ventilator nebulizer menu and nebulizer cable. The Aerogen Pro and Aerogen Solo are purchasable parts, see "Parts and accessories" section for ordering information. The Aerogen Pro and Aerogen Solo (disposable) may be used with neonatal, pediatric, and adult patients in acute and subacute care environments. Both nebulizer models operate without changing the patient ventilator parameters and can be refilled without interrupting ventilation. The nebulizers may be used with a neonatal, pediatric, or adult breathing circuit. The T-adapter for the nebulizer is specific to the breathing circuit type. Do not use a filter, heat-moisture exchanger or heatmoisture exchanger filter between the nebulizer and the patient airway. Use of a heat-moisture exchanger or nebulizer in the breathing circuit can substantially increase flow resistance when a nebulizer is active. Monitor the breathing system filter frequently for increased resistance and blockage. Use of an external pneumatic nebulizer may significantly impact volume delivery and monitoring, decrease trigger sensitivity, and cause alarms if external flow is introduced and Pneumatic Nebulizer Flow Compensation is not used. It is strongly recommended to use an expiratory filter when a nebulizer is used to help protect the expiratory flow sensor.1 INSP EXP EXP AB.100.191 T otal Spon t Menu Adult Cur rent Mod e FiO 2 30 % Pins p 33 cmH2 O Rate 10 /mi n Tins p 1.7s PEE P 5 cmH2 O PS 5 cmH2 O Standb y Ins p Hol d Exp Hol d Manua l Breat h 14:3 8 FiO 2 No Alarm s Ai r way Pressu re cmH2 O 60 40 20 0 -5 Pma x Ppea k PEE P VTexp 508 30 % 40 22 PEE Pe 5 cmH2 O 10 3 Peak P ressu re 40cmH2 O 50 10 Minu te Volum e 6. 2l/mi n 12 4 Tidal Volum e 508 ml 600 400 Respira tory Ra te 14 /mi n 20 5 Total Spont 3 4 2 5 6 1 Figure 4-7 • Overview of setup and connections with a humidifier 1. Humidifier (Fisher & Paykel) 2. Inspiratory safety guard 3. Inspiratory limb to and from humidifier to patient wye 4. Expiratory port/expiratory filter if used 5. Expiratory limb 6. Spacer (5 ml - minimum)