Basic Info.
Work Environment
Low-temperature Heat Pump
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CB, RoHS, SASO, Ec, ETL, cETL, SAA, VDE, En14511-2:2011, ISO14001
Heater Exchanger
Plate Heater Exchanger
Max Heating Outp
70 Centigrade
Transport Package
5 Layer Strong Carton
Specification
CE, RoHS, SGS, SASO
Production Capacity
30000PCS/Year
Product Description
By using the latest inveter+EVI technology, HEEALARX commercial air to water heting and cooling heat pump is designed as a high energy-efficient and stable heating solution, with wide heating capacity from 50kW to 80kW. Not only with inverter compressor, it can adjust working speed according to heating demand automatically, to optimize the efficiency of the whole system, but also with EVI technology, it can always provide stable heating output, to minimize your energy consumption in cold winter. HEEALARX Commercial air to water heating cooling heat pump is a simple but powerful solution, which meets heating, cooling and stabel hot water demand for commercial applications, such as apartments, hotels, and schools, etc.
Features of HEEALARX Commercial Inverter Air to Water Heating Cooling Heat pump:
1Hot water up to 60ºC,suitable for underfloor/radiator heating
2.With EVI system,can work stable at ambient temperature -30C to 45C
3.Full inverter system,Stable and efficient performance.
4.R32 System,environment friendly
5.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water
6.With Wifi App control
Dimension of the unit
Specification
Model | / | VS600-DC | VS700-DC |
Power Supply | / | 380V-400V~/3N/50Hz | 380V-400V~/3N/50Hz |
Heating Condition-Ambient Temp.(DB/WB): 7/6ºC, Water Temp.(In/Out): 30/35ºC |
Heating Capacity Range | kW | 14.0~60.0 | 15.0~70.0 |
Heating Power Input Range | kW | 2.65~14.46 | 3.06~17.07 |
COP | kW/kW | 5.28~4.14 | 4.90~4.10 |
Heating Condition-Ambient Temp.(DB/WB): 7/6ºC, Water Temp.(In/Out): 50/55ºC |
Heating Capacity Range | kW | 12.5~56.0 | 14.2~65.5 |
Heating Power Input Range | kW | 3.93~19.65 | 4.47~22.98 |
COP | kW/kW | 3.18~2.85 | 3.18~2.85 |
Cooling Condition-Ambient Temp.(DB/WB): 35/24ºC, Water Temp.(In/Out): 12/7ºC |
Cooling Capacity Range | kW | 11.0~44.0 | 12.5~50.0 |
Cooling Power Input Range | kW | 3.10~15.44 | 3.47~22.59 |
COP | kW/kW | 3.55~2.85 | 3.60~2.90 |
Max. Power Input | kW | 20.0 | 24.0 |
Max. Current lnput | A | 36.4 | 43.6 |
ErP Level (35ºC) | / | A+++ | A+++ |
ErP Level (55ºC) | / | A++ | A++ |
Water Flow | m³/h | 10.32 | 12.04 |
Refrigerant | / | R32 | R32 |
Proper Input | kg | 3.2×2 | 4.0×2 |
CO2,Equivalent | Tom | 2.16×2 | 2.7×2 |
Sound Power Level | dB(A) | 68 | 68 |
Operating Ambient Temperature | ºC | -25~43 |
Max. Water Temperature | ºC | 60 |
Compressor Brand | / | |
Water Side Heat Exchanger | / | Plate type |
Water Side Heat Exchanger Brand | / | famous brand |
Water Pressure Drop (max) | kPa | 30 | 30 |
Fan Motor Type | / | DC Moter |
Fan Quantity | / | 4 | 4 |
Water Connection | inch | G2" | G2" |
Cabinet Type | / | Galvanized sheet |
Unit Dimension(L/W/H) | mm | 1965×820×1480 | 2070×820×1630 |
Shipping Dimensions(L/W/H) | mm | 2055×870×1630 | 2160×870×1780 |
Net/Gross weight | kg | 360/410 | 450/500 |
The above data is for reference only; specific data is subject to the product nameplate. |
Parts we are using:
HEEALARX commercial full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from PANASONIC or famous brand, inverter fan motor, AL-FA LA AL plate heater exchanger, digital touch controller with WIFI
Advantage of HEEALARX commercial full DC Inverter air to water heating cooling heat pump monoblock
1. Full DC Inverter technology:
With Panasonic twin rotary compressor and also panasonic brushless inverter fan motor.
Evi Technology:
Evi technology is adopted so that unit can function well under low ambient temperature of -30 centigrade low temperature.
2. Wifi Control:
Wifi control is applicated in our full dc inverter heat pump system.
Warranty:
years on the whole system.
Low noise level
Special design of air system which can work in super quiet condition with low noise level of 39db.
Modern Touch Controller
Modern touch controller can intergrate with indoor thermostat.
* Low Noise
With Panasonic rotary compressor and DC inverter brushless fans, our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level.
* Smart WIFI Control
The intelligent controller with RS485 WIFI APP is adopted to realize the linkage control between the heat pump unit and the terminal application end. With the Cascade function, multiple units can be controlled with one panel.
* Wide Voltage Application
The DC Inverter Air Source Heat Pumps operate normally within the voltage range of 150V-260V (1ph) or 330V-450V (3ph) to reduce the impact of voltage instability on the environment.
* Intelligent Defrosting
The smart defrosting technology makes optimal defrosting decisions to minimize energy consumption and improve customer satisfaction.
* Modern touch controller
Modern touch controller can intergrate with indoor thermostat.
Mass Production Details For Inverter House Heating Heat Pumps
Brief Introduction Regarding HEEALARX Heat Pump Manufacturer