| US$3,000.00-6,000.00 | 1 Piece (MOQ) |
| Product highlights * Linux operation system * ARM CPU * Digital signal and processor * Continous hard work for 10000 hours * Energy saving design * High penetration * Good quality images | |
| Physical Specifications | |
| Unit weight (kgs) | 450 |
| Unit size (mm) | 2194.7(L)*902(W)*1362.5(H) |
| after packed in wooden pallet - | |
| Gross weight (kgs) | 650 |
| Packing size | #1: 237*105*166cm |
| #2: 86*87*142cm | |
| General Specifications | |
| Tunnel size(mm) | 658(L)*495.5(W) |
| Conveyor Speed(m/s) | 0.2 |
| Conveyor height(mm) | 700 |
| Conveyor Max Load(kgs) | 200 |
| X ray dose per each inspection | Typical 2.0 μGy, guarantee 2.5 μGy |
| X ray leakage | Typical 1.0 μGy/h, guarantee 1.5 μGy/h |
| Penetration | Typical 30mm, guarantee 27mm |
| Wire Resolution | Typical AWG38, guarantee AWG36 |
| Penetration Resolution | Typical AWG30, guarantee AWG30 |
| Spatial resolution: | Typical dia1.0mm,Vertical: dia1.0mm; Guarantee dia1.3mm,Vertical: dia1.3mm; |
| Power Consumption | 0.5KVA |
| Noise | < 60 dB |
| Film Safety | Guarantee ASA/ISO1600 Film |
| X-ray Generator (single) | |
| Anode Voltage | 140 KV |
| Anode power | 0.5mA |
| Generate angle | 80 degree upward |
| Generate direct | from bottom to top |
| Cooling / Duty Cycle | Oil Cooling /100% |
| Brand | made by ourself |
| Software System | |
| Self-test after power on | Self test after power-on, and show the problem ( 1. emergency stop, 2. housing panel is open 3. calibration fail 4. detection system error 5. hard drive is missing) |
| Image Display | High resolution of 1024 * 1280 pixel; |
| Image Enhancement | Color/BW, negative, high/low penetration, organic /inorganic Stripping, general enhancement, and pseudo color, etc. |
| Image Recall | 30 images recallable, retrieval |
| Image Archive | Up to 500,000 images stored automatically, enable transferring to USB disk, and converting to JPG, BMP and other general formats |
| Real-time Curve | Real-time curve to see if the detection system and other components work well |
| Others | Fault diagnosis, system time setting, detection blind dots delete, x-ray source setting(analoge or digital), alarm setting, images setting, software register, user management, TIP report, data setting(machine working time, x-ray source working time, baggage counter, etc.) |
| Operating Environment | |
| Operation temperature/Humidity | 5ºC-40ºC / 0%-90%(non-condensing) |
| Storage Temperature/Humidity | -40ºCto 70ºC / 5%-95%(non-condensing) |
| Operation Power | 220VAC(±10%) 50±3Hz (Optional: 100VAC,110VAC,120VAC,200VAC) |
| Computer and other | |
| Monitor | High Resolution Color, LCD Accord, 17inch |
| Hard Disk | SEAGATE 500G 3.5" |
| CPU | Cortex A9 |
| Storage | 1GB |
| Main board | IMX6_mainboard-V030, made by Safeway |
| Compliance | |
| International | * ISO19001 ; ISO14001 ; OHSMS18001 ; * CE * USA FDA * Maximum X-ray leakage of less than 5 μSv/h(0.5mR/h) measured at 5cm from any external surface. (European standard - less than 1 μSv/h(0.1mR/h) measured at 10cm from any external surface) |
| National (China) | * Health Inspection Report * Computer Software Copyright Registration Certificate * Software Product Registration Certificate * Radiation Safety Certificate from Ministry of Public Security * Quality Certification from Safety andElectronic Products Quality Inspection Center * Design pantent certification: Patent No. : 201020700245.2 ; Patent No. : 201020700245.8 ; Patent No. : 201020700256.0 |
| X-Ray Baggage Scanner Product Index | |||||
| NO. | Model | Remarks | |||
| Tunnel Size | Generator | View | Brands of Generator | ||
| 1 | AT 5030C | 500*300mme | single | one | self made |
| 2 | AT 6040B | 600*400mm | single | one | Spellman 160 Kv |
| 3 | AT 6550B | 650*500mm | single | one | Spellman 160 Kv |
| 4 | AT 8065B | 800*650mm | single | one | Spellman 160 Kv |
| 5 | AT 10080B | 1000*800mm | single | one | Spellman 160 Kv |
| 6 | AT 10080D | 1000*800mm | two | two | self made |
| 7 | AT 10080T | 1000*800mm | three | three view / 3D | self made |
| 8 | AT 100100B | 1000*1000mm | single | one | Spellman 160 Kv |
| 9 | AT 100150B | 1000*1500mm | single | one | Spellman 200 Kv |
| 10 | AT 150180B | 1500*1800mm | single | one | Spellman 200 Kv |
| 11 | AT 2300 | Portable and mobile x-ray scanner | |||
| Available and customizable models | |||||
| NO. | Model | Remarks | |||
| Tunnel Size | Generator | View | Brands of Generator | ||
| 1 | AT 100100D | 1000*1000mm | two | two | self made |
| 2 | AT 100100T | 1000*1000mm | three | three view / 3D | self made |
| 3 | AT 150100B | 1500*1000mm | single | one | Spellman 160 Kv |
| 4 | AT 100150D | 1000*1500mm | two | two | self made |
| 5 | AT 150180D | 1500*1800mm | two | two | self made |